Flexible Rack-Mounted Multimedia Enclosure.



Features:

  • Features a low-profile design for configuration with up to four storage devices in a 1U space in a 19-inch rack
  • Offers Linear Tape-Open (LTO) Ultrium 6 and Ultrium 5 tape drives, DVD-RAM or RDX removable disk drives
  • Provides multiple options to connect to high-performance Flex System, System x and ThinkServer servers
  • Enables the performance and capacity enhancements of half-high LTO Ultrium 6 and 5 tape drives, with the additional versatility of RDX removable disk drives and DVD-RAM options


Specifications:

Available Configuration
61901U3 / 61901UX
Number of Storage Devices
Four maximum (assumes four DVD drives)
Electronics
Optional SAS, USB or Fibre Channel electronic bus
Typical Compression
2:1 for tape drives and 3:1 for DVD optical drives
Compression on RDX disk drives is typically 2:1
Service Offerings
One-year limited warranty
Customer-replaceable unit and 24x7 on-site service, service upgrades available
Dimensions (H x W x D)
4.3cm x 48cm x 43.8cm (1.7in. x 18.7in. x 17.6in.)
Weight
7.1kg (15.6lbs) – typical configuration
Temperature
10°C – 40°C (50°F – 104°F)
Relative Humidity
20% – 80%
Wet Bulb (Maximum)
26°C (79°F)
Electrical Power
0.047 kVA
Power Requirement
140W power supply
Acoustics (Maximum)
5.5 bels idle; 6.2 bels operating
Host Operating Systems
Windows Server 2008, 2008 R2, 2012, 2012 R2; RHEL 5, 6, and 7; SUSE Linux Enterprise Server 10 and 11
SAS Connectivity
LTO Ultrium drives support SAS attach to System x and ThinkServer systems
USB Connectivity
RDX drives can be connected to an external USB 3.0 port on System x, and ThinkServer servers and Flex System compute nodes

DVD-RAM drives with USB interface can be connected to an external USB 2.0 port on System x and ThinkServer servers
Fibre Channel Connectivity
LTO Ultrium drives support FC switch-based attachments for Flex System compute nodes

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.